Model CTV voltage output flexible "rope type" Rogowski current transformer

Models 100A to 10,000A for Three Phase and Single Phase systems with 0-0.333V, 0-5V, 0-10V

Powertek
UK Tel: +44 1788 519911
US Tel: +1 631 615 6279
Email : info@powertekus.com
Email : info@powertekuk.com

return to homepage | info@powertekuk.com | contact us

Click here for mobile friendly version page


CTV flexible "rope-type" current transformer, current ranges from 100A to 10,000A



CTV Conditioner supplied with Din Rail Mount

The CTV current sensors are the world's first flexible 'clip-around' current probe with 0.333V and optional 5A output, allowing compatibility to existing 0.333V metering circuits and 5A metering.  Unlike conventional CTs, there are no open circuit hazards - ideal for retrospective metering projects and installations in confined spaces where installation of conventional iron core CTs is not possible.  The CTV flexible current sensor also simplifies installation and eliminates the need for expensive LV/HV plant shutdown.


The CTV current sensors convert ac current to an isolated 0-0.333V, 0-5V or 0-10V with available ranges from 100A to 10,000A.  Because the current sensors are flexible split core, installation is possible without shutting down the LV electrical supply, avoiding expensive down-time costs. Typical applications are retrospective energy monitoring in factories, offices buildings, process control data logging systems, where power, energy and current monitoring is important.  Typical applications are factories, offices buildings, ac/dc VFD drives, welding, power conversion and power distribution.  For all CTV current sensor models, an A2LA NIST/NPL (UKAS) traceable calibration certificate and certificate of conformance is supplied. All CTV sensors use UL94V0 or CSA approved materials.  
The CTV flexible current sensors are suited to permanent or semi permanent installation. The coil sensor is durable, lightweight, flexible and will easily clip-around a power cable. The optional 5A output (CTA) connects direct to installed 1A or 5A metering, rotary metering or current transducers.
 
bullet

Suitable for single or three phase systems

bullet

Available sense coil diameter 100mm or 160mm

bullet

Isolated measurement output

bullet

Voltage outputs 0.333V, 0-5V and 0-10V

bullet

1kV insulation continuous (tested 7.4kV)

bullet

<0.5% accuracy

bullet

Flat frequency response from 20Hz to 5000Hz

bullet

110Vac-240Vac power standard, optional 24Vdc, 48Vdc or 125Vdc

bullet

Operating range -20°C to +65°C

bullet

Safety EN61010-1 1000Vac CATIII, 600Vac CATIV CE marked, UL94V0 flame retardant

CTV Metering applications


E50 Power Meter Data Sheet and User Guide

CTV Models and order codes

 

 

CTV/100/5V/2/100 CTV/1600/5V/2/100
CTV/200/5V/2/100 CTV/1800/5V/2/100
CTV/300/5V/2/100 CTV/2000/5V/2/100
CTV/400/5V/2/100 CTV/2500/5V/2/100
CTV/500/5V/2/100 CTV/3000/5V/2/100
CTV/600/5V/2/100 CTV/3500/5V/2/100
CTV/700/5V/2/100 CTV/4000/5V/2/100
CTV/800/5V/2/100 CTV/5000/5V/2/100
CTV/900/5V/2/100 CTV/6000/5V/2/100
CTV/1000/5V/2/100 CTV/7000/5V/2/100
CTV/1200/5V/2/100 CTV/8000/5V/2/100
CTV/1500/5V/2/100 CTV/10000/5V/2/100

CTV / Arms current / 5V output / cable length / coil diameter mm
0.333V or 10V outputs available

CTV specifications

CTV voltage output "Rope Type" Flexible Current Sensor Specifications

The Powertek CTV flexible sensor & conditioning module are supplied as calibrated sets with a traceable calibrated voltage output.

Current Sense coil
Diameter: 100mm/3.93" or 160mm / 6.3" clip-around split core construction
Thickness: 8mm / 0.31"
Material: Flexible Thermoplastic rubber, flame retardant UL94VO
Working voltage: 1000V at 50/60Hz CAT III, tested 7400V 50/60Hz 1 minute

Cable
1000V UL style 20940, 5mm dia, 3metre length

Conditioner-amplifier
Casing: Din Rail module UL94V0 and CSA approved polycarb, 250mm total length
Fundamental Frequency: 20Hz to 5000Hz
Bandwidth: 20Hz-5000Hz
Output rating: Max load 10kohms
Phase shift: 0.04° at 50/60/400Hz
Accuracy: <1.0% accuracy
Input impedance: 100kohm
Accurate with waveform crest factors: 1 - 5
Input ranges: 100A to 10,000Arms
Power: 110Vac-240Vac power, optional 24Vdc, 48Vdc and 125Vdc
Includes: Conditioner and inst. PSU and output CT (5A)

Environmental
Operational range -
20°C to +65°C



Optional CTA 5A current output module

Available CTV current sensors
100A, 200A, 300A, 400A, 500A
600A, 700A, 800A, 900A, 1000A
1200A, 1500A, 1600A, 1800A, 2000A
2500A, 3000A, 3500A, 4000A, 5000A
6000A, 7000A, 8000A, 10000A

Standard units work at all power frequencies 50Hz, 60Hz or 400Hz

 

Available sensor types

All products have CE, IEC, EN, ASME or BS approvals

Return to Homepage