Powertek Logo
UK Office:
US Office:

DC Current Sensors for Industrial, Automation, Rail Transport, Welders, DCS and Electric Vehicles

Converting dc current to an isolated voltage or current loop. Optional interfaces

The CTH current sensors convert dc current to an isolated voltage or mA output with instantaneous precision. The CTH output is a faithful reproduction of the measured current, whether ac or dc. All popular EV types, process control voltage and current loop outputs are available. Through hole or split core options mean that connection is non-intrusive and straightforward. The available input range of the CTH sensors is any value from 1A to 40000Adc. Optional dc offset control allows nulling of residual dc current to ensure best use of the output span. The sensor power input is designed to operate over a wide voltage range associated with process control and sub-station auxiliary dc supply systems. Active Hall Effect sensor technology allows measurement from DC-150kHz (depending on the sensor type) along with fast step response. The CTH can be used to provide an instantaneous output for ac currents. Typical applications are found in process control systems like PLC or SCADA, transportation, telecommunications, dc drives, welding and circuit breaker trip coils. For all CTH models, a NIST/NPL (UKAS) traceable calibration certificate and certificate of conformance is supplied.

More Info On: Our AC / DC Transducers

EV and Outdoor models along with weather proof cabling available

For alarm, protection and threshold monitoring please click Din-rail trip relay

CTH through hole core Type 1

  • Type 1: Hole: 13.5mm (0.53") x 10mm (0.39")
  • Overall size 145mm (5.71") x 95mm (3.74") x 38mm (1.50")
  • Type 1 current ranges: 1 / 2 / 5 / 10 / 20 / 30 / 40 / 50 / 75 / 100A
dc transducer
Type 1: DC-100kHz (internal filter 1500Hz). As standard the sensor is supplied connected via a 100cm (39") cable

CTH Type 2

  • Type 2 current ranges: From 0-5A to 0-600A, 25.4mm dia
dc transducers

Type 2 - 24.5mm through hole DC-150kHz (internal filter 1500Hz) As standard the sensor is supplied connected via a 100cm (39") cable

CTH Split core Type 3 For EV

  • Hole diameter 28.45mm (1.125") Overall size 78.74mm (3.1") x 63.5mm (2.5") x 33mm (1.3")
  • Current ranges: 50 / 100 / 200 / 500 / 1000 / 2000 / 5000A
CTH through hole dc transducers
Type 3 through hole DC-10kHz, optional low pass filter

CTH Type 3 CTU Datasheet

CTH split core Type 5

  • Hole diameter 21mm (0.82") Overall size 69mm (2.72") x 46mm (1.81") x 22mm (0.87")
  • Current ranges: 20 / 30A/ 40 / 50 / 100 / 200 / 300 / 400A split core models.
CTH split core dc transducer

Type 5 split core DC-25kHz (internal filter 1500Hz). As standard the sensor is supplied connected via a 100cm (39") cable

CTH split core Type 6 / CTH split core Type 7

CTH split core Type 6:
  • Hole: 104 (4.09") x 40mm (1.57") Outer: 159mm (6.26") x 85mm (3.35") Current ranges: From 200A to 4000A
CTH split core Type 7 :
  • Hole: 163mm (6.42") x 50mm (2")Outer: 233mm (9.17") x 95mm (3.74") Current ranges: From 500A to 4000A
CTH split core Type 6 / CTH split core Type 7
Type 7: DC-10kHz (internal filter 1500Hz). As standard the sensor is supplied connected via a 2.4m (8ft) cable

CTH Type 4 mini and CTH split core Type 8 mini

  • Hole: 28.5mm (1.125") round hole
  • Outer: 102 mm (4") x 80mm (3.125") x 19mm (0.75")
  • Current ranges: 100 / 200 / 300 / 400A
CTH Type 4 mini and CTH split core Type 8 mini

Type 8 mini split core DC-400Hz supplied with 8ft cable

CTH Type 4 and CTH split core Type 8

  • Hole: 50mm (2") round hole Outer: 127mm (5") x 105mm (4.125") x 31.75mm (1.25")
  • Current ranges: CTH / 200 / 300 / 400 / 500 / 800 / 1000 / 1500 / 2000 / 2500A
CTH through hole core
Type 8 split core DC-400Hz supplied with 8ft cable

CTH Type 9z

  • Hole: 115mm x 33mm (4.5" x 1.25") rectangular hole
  • Outer: 199mm x (7.83") x 99mm (3.90") x 34mm (1.34")
  • Current ranges: CTH / 200 / 300 / 400 / 500 / 800 / 1000 / 1500 / 2000 / 2500 / 3000A
CTH through hole core
Type 9z split core DC-400Hz
CTH through hole core
Type 9z with extended cable

CTH Type 8F

  • Hole: 57mm (2.25") round hole Outer: 137mm (5.375") x 134mm (5.25") x 42.00mm (1.625")
  • Current ranges: CTH / 200 / 300 / 400 / 500 / 800 / 1000 / 1500 / 2000 / 2500A
CTH Type 8F
Type 8F split core DC-400Hz supplied with 8ft cable

CTH Type 8EE

  • Hole: 108mm (4.25") round hole
  • Outer: 184mm (7.25") x 159mm (6.25") x 42.00mm (1.625")
  • Current ranges: CTH / 200 / 300 / 400 / 500 / 800 / 1000 / 1500 / 2000 / 2500 / 5000A
CTH Type 8EE
Type 8EE split core DC-400Hz supplied with 8ft cable

CTH Type EE terminals on sensor head

  • Hole: 108mm (4.25") round hole
  • Outer: 184mm (7.25") x 159mm (6.25") x 42.00mm (1.625")
  • Current ranges: CTH / 200 / 300 / 400 / 500 / 800 / 1000 / 1500 / 2000 / 2500A

CTH Type D split core terminals on sensor head

  • Hole: 28.5mm (1.125") round hole
  • Outer: 116.59mm (4.59") x 73.4mm (3.125") x 19mm (0.75")
  • Current ranges: 100 / 200 / 300 / 400 / 500A

CTH split core Type G

  • CTH Hole size 76.2mm (3.0") x 165.1mm (6.5")
  • Outer 196.85mm (7.75") x 304.8mm (12")
  • Current ranges 1000 / 2000 / 3000 / 4000 / 5000 / 6000A
CTH split core Type G
Type G split core DC-400Hz supplied with 8ft cable
CTH Type G Datasheet

CTH split core Type 10

CTH split core Type 10
  • CTH Hole size 140mm (5.5") x 203mm (8"). Outer 254 (10") x 350 (13.75")
  • Current ranges 5000 / 6000 / 7000 / 8000 / 9000 / 10000 / 15000 / 20000A
CTH split core Type 11
  • CTH aperture 330mm (13") x 330mm (13"). Outer 534mm (21") x 534mm (21")
  • Current ranges 25000 / 30000 / 35000 / 40000Adc
CTH split core Type 10
Type 10 & 11 split core DC-1kHz

CTH Type G, 10 and 11 Data Sheet
CTLP Compact Loop Powered DC Current Transducers
  • CTLP Compact Type Loop Powered, ranges:
    CTLP 25 / 50 / 100 / 400 / 500 / 600 / 800 / 1000A
CTLP case A
CTLP case A models 25A, 50A and 100A

CTLP 25A Datasheet
CTLP case Z models
Molded integral 8ft cable for intrinsically safe connection
CTLP Datasheet

Signal conditioner terminal connections

Signal conditioner

Terminals numbers used in DC Current Transducer Config:

Inst. Power: 13/14 +ve/-ve | Sensor 15(wht) 16(Red) 17(blk) 18(Grn)| Outputs: 7/8 4-20mA 9/10 0-10V (7, 9 grounds)

Input and output grounds are isolated 300V

Signal conditioner overall size 106mm (4.187") x 90mm (3.5") x 32mm (1.25")

DC current transducers general specifications
Ranges
Depending on core type: 1A / 2A / 5A / 10A / 20A / 30A / 40A / 50A / 100A / 200A / 500A / 1000A / 2000A / 3000A / 4000A / 5000A / 6000A / 10000A / 20000A / 25000A / 30000A / 35000A / 40000A Amps peak
Outputs
0-100mV, 0-1V, 0-2V, 0-5V, 0-10V, 4-20mA. All CTH outputs can be bipolar / instantaneous. Non-standard outputs are available, USB, RS485 and WiFi interfaces available
Core type
Through hole or split core clamp type, sense method based on dc Hall Effect
Insulation voltage rating
Type 1, 2 & 5 rated insulation (Galvanic) 2.5kVpk 1 min 50/60Hz. Type 6 & 7 3kVpk 1 min 50/60Hz. Type 4 & 8 5kVpk 1 min 50/60Hz
Power input
5V / 12Vdc / 24Vdc / wide range 9-36Vdc / 48Vdc / 72Vdc / 110Vdc / 125Vdc / 250Vdc / 115Vac / 230Vac - all fuse, polarity and surge protected
Accuracy
±0.5% for a non split core, ±1.0% for a split core. Conditions +23°C ±5°C, traceable to UKAS NPL/NIST USA
Working temperature range
Typically -20°C - 65°C (can be extended, check for exact model). Functional temperature range –20°C - 70°C (check for each model). CTH types 1 & 2 are –40°C - 85°C (sensor head only)
Protection
Input fuse, output fuse, power input polarity diode, spike suppression
Frequency Response
Depending on sensor type/model. Type 1 & 2 DC- 150kHz max. Type 5, 6, 7, 8 & 9 split cores are DC-10kHz max. Standard HF cut-off filter is 1.5kHz (other values available)
Adjustment
Internal dc offset and gain controls
Mounting
All signal conditioners and sensors have fixing points. Current sensors up to 400A can be mounted on the signal conditioner case or via a cable.
Approvals
CE Marked, EN61010 cat II & IEC348, UL/CSA rated materials. Self extinguishing materials to UL94V0
Warranty
2 year warranty

Available through hole sizes (some not pictured above)

Type 1: 13.5 x 10mm rectangular 1A – 100A – Supplied attached or separate to conditioner

Type 2: 24.5mm diameter 5A - 600A – supplied with 1 metre (39") from sensor - signal conditioner

Type 3: New Part

Type 4 mini: 28.5mm / 1.125" diameter 100A - 400A Sensor has integral signal conditioner supplied with 2.4M cable

Type 4: 50mm diameter / 2" diameter 100A - 3000A Sensor has integral signal conditioner supplied with 2.4M cable

Available split core hole sizes

Type 5: 21mm dia 20A - 400A supplied with 1 metre (39") cable from sensor - signal conditioner

Type 6: 104 x 40mm 500A - 3000A supplied with 1 metre (39") cable from sensor - signal conditioner

Type 7: 163 x 50mm 500A - 4000A supplied with 1 metre (39") cable from sensor - signal conditioner

Type 8 mini: 28.5mm / 1.125" dia 100A - 400A Sensor has integral signal conditioner supplied with 2.4M cable

Type 8: 50mm / 2" dia 100A - 3000A Sensor has integral signal conditioner supplied with 2.4M cable

Type 8F (maxi): 57.15mm / 2.25" dia 400A - 3000A Sensor has integral signal conditioner supplied with 2.4M cable

Type 8EE: 108.00mm / 4.25" dia 400A - 3000A Sensor has integral signal conditioner supplied with 2.4M cable

Type 9z: 115mm (4.5") x 33mm (1.25") 200A - 3000A Sensor connects to signal conditioner via 2.4M cable

Type G: 76.2mm x 165.1mm / 3.0" x 6.5" 2500A - 5000A Sensor has integral signal conditioner supplied with 2.4M cable

Type 10: 140mm (5.5") x 203mm (8") 5000A - 20000A Sensor connects to signal conditioner via 2.4M cable

Type 11: 330mm (13") x 330mm (13") 25000A - 40000Adc Sensor connects to signal conditioner via 2.4M cable

Longer cable lengths available - on request

Current transducer order codes

The order code is based on:-

CTH / amps input / output / SC or TH / power input + core type

SC = split core, TH = through hole (non-split core)

Note: 230Vac/dc and 115Vac/dc adapters are available (in this case the CTH will be supplied with 9-36Vdc input and ac adapter)

Options R : Ruggedization (not available for all sensor types)

Option T : Extended temperature range -40°C - 85°C (not available for all sensor types)

Options : noise rejection and offset, user can specify upper or lower frequency –3db point

Non standard input current

Non standard output voltage, current (25mA, 1A, 5A), USB, RS485 and WiFi interfaces available

All models constructed with self extinguishing materials to UL94V0 and CSA

Current transducer order codes

CTH / 50A / 4-20 / TH / 24Vdc type 1
50Adc input, 4-20mA output, through hole, 24V aux power input, core type 1 (13.5 x 10mm)
CTH / 400A / 10 / TH / 48Vdc type 4
±400Adc input, ±0-10V output, through hole, 48Vdc aux power input core type 4 (50mm hole dia)
CTH / 800A / 5 / SC / 9-32Vdc type 8 RS485
±800Adc input, ±0-5V output, split core, 9-32Vdc aux power input, core type 8 (50mm hole dia) RS485 interface
CTH / 2000A / 4-12-20 / SC / 110Vdc type 7
±2000Adc input, 4-12-20mA output (12mA = zero), split core, 110Vdc aux power input, type 7 core (163 x 50mm)