CRD-005 and CRD-020 Programmable Setpoint Relay
Protection relay, trip relay


Voltage and current input ranges from 0-1mAdc, 0-10Vdc, 0-5Aac to 0-20Aac

Powertek
UK Tel: +44 1788 519911
US Tel: +1 631 913 3242
Email : info@powertekus.com
Email : info@powertekuk.com

return to homepage | info@powertekuk.com | contact us
 

The CRD-020 and CRD-005 Programmable Set-point Relays are used for protection, voltage and current threshold sensing to within 1%, control and trip applications


 

CRD-020 Programmable Setpoint Relay

CRD-020 Datasheet for AC current 0-5A, 0-10A, 0-20A input

CRD-005 Datasheet for 0-1mAdc and 0-10Vdc input

CRD Series User Manual
 

Setpoint Relay Features

bullet

CRD-020 Programmable ac current set-point relay setting for threshold levels, over and under-current
operation

bullet

CRD-005 Programmable dc voltage and mA set-point relay setting for threshold levels, over and
under-voltage operation

bullet

CRD-005 internal DIP-switches allow for either 0-1mAdc or 0-10Vdc operation, and may be set for
under-alarm or over-alarm relay operation

bullet

CRD-020 internal DIP-switch allow configuration of the ac current range to either 0-5A, 0-10A, 0-15A or
0-20A and the relay mode for under-current or over-current operation

bullet

Lid mounted two digit numerical push button switch calibrated as percent of full scale with a threshold range of 1-99%

bullet

Red LED lamp lights to indicate when the threshold level has been tripped

powertek

powertek

Highlighted area indicates Factory Setting. The CRD-020 unit is shipped from the factory with a 0-5Amp ac input and in an over-current relay mode. The set point relay can be set to provide any one of the four current ranges and modes of operation.

* The output relay will energize when instrument power is applied and the current is above the set point threshold. It will remain in a "Fail Safe" mode until either the input current drops below the set point threshold or instrument power is removed.

** The output relay will energize when instrument power is applied and will remain in a "Fail Safe" mode until either the instrument power is removed or the input current exceeds the set point threshold level.

 

powertek

powertek


Ordering codes
CRD-005
0-1mAdc and 0-10Vdc input, 3A relay output, 110Vac powered
CRD-005Y18 0-1mAdc and 0-10Vdc input, 3A relay output, 24Vdc powered
CRD-020 0-20Aac input, 3A relay output, 110Vac powered
CRD-020Y18 0-20Aac input, 3A relay output, 24Vdc powered
 