ATH1ph single phase | ATH3ph Three Phase Current Transducer for ac or dc Current Sensing

The ATH single phase and three phase current transducer range converts dc or ac current to an isolated voltage or current loop output

Read more Get a quote

ATH1ph and ATH3ph current transducer
Supplied with Din Rail mounting kit

Features

Product Specifications

  • Available input ranges 100mA / 200mA / 1A / 2A / 5A / 10A rms ac or dc.  Operational from 10% - 125% of range
  • Outputs: 50mV, 100mV, 1V, 5V, 10V, 4-12-20mA or 4-20mA (4-20mA dc amps input only or ATHR models).  Unipolar or bipolar configuration
  • Auxiliary power input 5V/9-36V/48/110/230 Vdc or Vac.  Max current draw 24Vdc 50mA max
  • Fast response time <200uS (no filtering).  Standard frequency range is DC-10kHz
  • Certified accuracy better than <1.0% at +23°C ±5°C, traceable to NIST/NPL (5 minute warm up)
  • Internal gain calibration controls
  • Based on isolation amplifier for 1.5kV
  • Working temperature range 0°C - 50°C
  • Functional temp range –10°C -70°C
  • Rated working voltage insulation 1.5kVpk, flash tested 2.5kV for 1 minute
  • Screw terminal input/output connections IP30
  • 3.5 mm fixing holes
  • CE Marked
  • UL94V0, IEC1010 cat II, IEC348, DIN 57411
  • Case IP50, terminals IP30 complies with IEC529
  • 1 year warranty

Description

The ATH current transducer range converts dc or ac current to an isolated voltage or current loop output.   The ATH sensors are direct connecting, meaning they connect in the circuit under test eliminating CT limitations and errors.  The available ATH models cover the range from 0-100mA to 0-5Arms, operating with fast response capability.  ATH are instantaneous conversion, the ATHR are rms converting where the ATHR device will give true rms conversion even with distorted waveforms, over DC-10kHz range.

The sensor power input is designed to operate over a wide range associated with process control and sub-station auxiliary dc supply systems.  Some typical applications are current monitoring in energy metering, industrial control, ac/dc drives, process control, rail transportation and circuit breaker trip coils.  For all products, a USA NIST, UK NPL traceable calibration certificate and certificate of conformance are available.   ATH and ATHR sensors are available in ac only or dc + ac configurations.

Non inductive Co-Axial Current shunt - CVR applications

  • Pulsed current applications
  • Calibration laboratories
  • Current sensing for phase meters
  • Single phase angle indicators V-A
  • Three phase phase angle indicators V-A
  • Cos Phi indicators
  • Power factor meters
  • High Frequency Watt Meters
  • Wideband Power meters
  • Power analysis
  • Current transformer calibration
  • Current probe phase delay
  • SCR current measurements
  • Current control of automatic welders
  • Measure output of automotive alternators
  • Fault current detection to determine bearing
  • Wear of Steam Turbine generators
  • EBW testing
  • Current detection in detonation systems
  • Three-phase fault testing in power transmission substations
  • Fault detection in modulators
  • Measurement of laser system currents
  • Chopper current control in electric cars
  • Circuit breaker testing
Current Transducer order codes

ATH / current range / freq / output / power input


Order code examples:

ATH / 5A / dc / 4-20 / 24Vdc
5Adc input, 4-20mA output with 24V aux power input
Calibrated 0-5Adc

ATH / 1A / ac + dc / 10 / 24Vdc
1Adc input, 0-10V output with 24V aux power input

Calibrated 0-1Adc

Order code examples (rms converting):

ATHR / 1A / ac+dc / 4-20 / 24Vdc

1Aac or dc input, 4-20mA output with 24V aux power input

Calibrated 0-1Arms

ATHR / 1A / ac / 4-20 / 24Vdc
1Aac input, 4-20mA output with 24V aux power input

Calibrated 0-1Arms (ac only)