The DP-40k differential voltage probes are an important accessory for any application involved in power electronics and high voltage systems.
About the DP-40k High Voltage Differential Probe
The DP40k differential voltage probes are an important accessory for any application involved in power electronics and high voltage systems. These probes allow isolated and floating measurments with any oscilloscope or data recorder, allowing the oscilloscope to remain grounded. Using a DP40k Differential probe, differential and floating (isolated) measurements can be made on a variety of ac power systems like 460V/230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope or DAQ. The DP isolation probes are powered from a battery or power supply.
DP-40K Differential probe applications:
| DP-40k High Voltage Differential Probe | |
|---|---|
| Differential Voltage DC/AC peak | 40kV |
| Bandwidth (50Ω load -3dB 4nS) | 20MHz |
| Common Mode Voltage DC/AC peak | 40kV |
| Common Mode Voltage RMS CATII / CATIII | 14kVrms |
| To Ground Maximum Voltage | 10kV CATIII |
| Attenuation(Switchable) | x500, x5000 |
| Input R (Each Input) | 50MΩ, >2% |
| Input C (Each Input) | <10pF |
| Maximum Operation Voltage (DC + AC peak) | ≤4kVpk at x500 |
| ≤40kVpk at x5000 | |
| Common Mode Rejection Ratio(CMRR) | 60Hz: > 10000:1 |
| 100Hz: > 1000:1 | |
| 1MHz: > 300:1 | |
| Noise (Into 50Ω Load) | ≤1mVrms |
| Input Impedance(Between Input) | 100MΩ // 1pF |
| Accuracy (at 20-30°C 70%RH after 20minutes) | ≤±2% |
| Maximum Output Voltage | 8Vp-p |
| Power Source | External 9V DC Adaptor |
| Other | Over Range Indication |