DP-8V High Voltage High Frequency Differential Probe

The DP‑8V 100MHz high‑voltage differential probe allows safe, isolated measurements up to 8kV for oscilloscopes and power‑electronic systems. Ideal for EV, motor drives, and high‑frequency switching applications.

Read more Get a quote


DP-8Vk, 100MHz differential voltage probe for isolation and safety
DP-8V 100MHz High Voltage Differential Probe

Highlights


  • 100MHz High Voltage differential probe
  • Max Input Voltage: ±400V DC / 8kVp-p / 2.8kVrms AC
  • Bandwidth: DC-100MHz
  • Input Impedance 20MΩ / 2pF
  • Attenuator: x10, x100, x1000
  • Max to ground voltage: 4kV CATIII
  • Output Impedance: 50Ω
  • Dual 4mm safety‑socket inputs
  • standard BNC output

  • Battery or external adaptor powered
  • Used to isolatation DAQ, oscilloscope and data loggers
  • Perfect for power electronic systems and EV (electric vehicle) power systems
  • Allows isolated floating measurements
  • Prevents ground loops and common mode issues
  • Cablibration Certificate provided
  • CATIII safety rating for industrial‑grade protection

Description

About the DP-15k Oscilloscope Differential Voltage Probe

The DP‑8V 8 kV 100 MHz High‑Frequency Differential Voltage Probe is an essential accessory for engineers working in power electronics, high‑voltage systems, and advanced switching applications. Designed to deliver safe, isolated and accurate measurements. It enables oscilloscopes, DAQs and data recorders to analyse high‑voltage circuits while remaining fully grounded. This isolation allows input signals to float at elevated potentials without exposing test equipment—or the user—to dangerous ground‑loop conditions.

With its wide DC–100MHz bandwidth, high input impedance, and excellent common‑mode rejection, the DP‑8V captures fast‑switching transients, PWM motor‑drive signals, and high‑frequency switching waveforms with precision. The probe supports switchable attenuation ranges ×10, ×100 and ×1000 making it suitable for everything from low‑voltage control circuits to high‑energy power stages up to 8kV peak‑to‑peak.

The DP‑8V is particularly valuable for differential and floating measurements across a wide range of AC and DC power systems, including 460V/230V/110V AC input supplies, chopped and switching power supplies, thyristor controllers, variable‑speed motor drives, motor inrush current analysis, and current‑shunt measurements. Its isolated input is provided through two secure 4mm safety/banana sockets, while the standard BNC output ensures seamless connection to oscilloscopes and DAQs.

Powered by either a 9 V battery or an external DC adaptor, the DP‑8V offers flexibility for both bench and field environments. Its robust insulation, CAT III safety ratings and low‑noise performance make it a reliable choice for EV power systems, inverter development, industrial drives and general high‑voltage research. Whether used for troubleshooting, design validation, or advanced diagnostics. The DP‑8V delivers the accuracy, safety and performance required in modern power‑electronics testing.

Applications

DP-100 Differential probe applications:

  • Testing 460V/230V/110V AC input power supplies
  • Analysis of switching and chopped power supplies
  • High‑frequency switching waveform capture in SMPS and converters
  • Differential and floating measurements on high‑voltage AC/DC power systems
  • Thyristor and SCR controller diagnostics
  • Floating measurement where ground reference is unsafe
  • Motor inrush current monitoring
  • Troubleshooting industrial drives, inverters, and power‑conversion stages
  • EV power systems
  • high‑voltage automotive electronics
  • Investigating ground loops and floating nodes
  • Isolation of oscilloscopes and DAQs during high‑voltage testing
  • PWM inverter signal measurement
  • Variable‑speed motor drives

Specification:

DP-8V 100MHz High Voltage Differential Probe
Differential Voltage DC/AC peak 4kV
Bandwidth (50Ω load -3dB 4nS) 100MHz
Common Mode Voltage DC/AC peak ±4kV
Common Mode Voltage RMS CATII / CATIII 1.4kVrms
To Ground Maximum Voltage 2kVdc 1.4kV CATIII
Attenuation(Switchable) x10: 80Vp-p
x100: 800Vp-p
x1000: 8kVp-p
Input R (Each Input) 10MΩ >2%
Input C (Each Input) <4pF
Maximum Operation Voltage (DC + AC peak) ≤80Vp-p at x10
≤800Vp-p at x100
≤8kVp-p at x1000
Common Mode Rejection Ratio(CMRR) 60Hz: > 80dB
100Hz: > 60dB
1MHz: > 50dB
Noise (Into 50Ω Load) ≤1mVrms
Input Impedance(Between Input) 20MΩ // 2pF
Accuracy (at 20-30°C 70%RH after 20minutes) ≤±2%
Maximum Output Voltage ±4Vpk
Power Source External 9V DC Adaptor
Other Over Range Indication

Full specifications for the differential probe DP-8V 100MHz are available in
DP-8V Specification
DP-8V Datasheet

Powertek specializes in the design and manufacture of electrical power, voltage and current measuring instrumentation
Contact Powertek today