DP-100 High Voltage Differential Probe

The differential probe DP-100 allows isolated and floating measurments with any oscilloscope or data recorder, allowing the oscilloscope to remain grounded.

Read more Get a quote

DP-100, differential voltage probe for isolation and safety
DP-100 High Volatge Differential Probe

Highlights

  • 6500 High voltage differential probe
  • Max Input Voltage: ±6.5kV DC / 6.5kVp-p
  • Bandwidth: DC-100MHz
  • Input Impedance 100MΩ // 1pF
  • Attenuator: x100, x200, x500, x1000
  • Max to ground voltage: 6.5kV CATIII
  • Output Impedance: 50Ω
  • PCL/Test printer output, IEEE488 interface included
  • Used for isolation of oscilloscope and data loggers
  • Suitable for power electronic systems and EV power systems
  • Allows isolated floating safe measurements
  • Prevents ground loop currents between test equipments
See more Differential Voltage probes

Description

About the DP-100 Oscilloscope Differential Voltage Probe

The DP100 differential voltage probes are an essential accessory for engineers working in power electronics, high‑voltage systems, and industrial energy‑conversion applications. Designed for safe, accurate and isolated measurements, the DP100 enables reliable oscilloscope observation of high‑potential signals while keeping the oscilloscope securely grounded—making it indispensable for environments where standard single‑ended probes cannot be used.

The DP100 differential voltage probes are an important accessory for any application involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, allowing the oscilloscope to remain grounded. Using a DP100 differential probe, differential and floating (isolated) measurements can be made on a variety of AC power systems like 460V/230V/110V AC input power supplies, chopped and switching power supplies, thyristor controllers, variable‑speed motor drives (PWM signals), motor inrush current and measurement across current shunts.

Engineered for versatility and safety, the DP100 features isolated inputs via two 4mm safety banana sockets, ensuring secure and reliable connection to high‑voltage test points. The BNC output provides effortless compatibility with oscilloscopes and DAQ systems, enabling clean, stable waveform capture across a wide range of power‑electronics environments.

The DP isolation probes are powered from a battery or an external power supply, offering flexibility for both bench and field use. With strong common‑mode noise rejection, high input impedance and robust insulation The DP100 delivers accurate differential measurements even in noisy, high‑EMI switching environments.

Ideal for R&D labs, industrial maintenance teams, academic programs and system validation engineers. The DP100 is the go‑to solution for safe floating measurements, high‑voltage differential accuracy and reliable oscilloscope performance in demanding power‑electronics applications. Its combination of safety, measurement fidelity and broad application coverage makes it a trusted tool for modern high‑voltage diagnostics.

Applications

DP-100 Differential probe applications:

  • Floating measurement where ground reference is unsafe
  • High‑voltage differential measurement up to 7 kV
  • Switch Mode Power Supplies primary‑side waveform capture
  • Motor drive inverter analysis
  • High‑side gate‑drive measurement like IGBT, MOSFET
  • Investigating ground loops and floating nodes
  • Floating gate drivers analysis(bootstrap circuits)
  • Measuring common‑mode noise in switching converters
  • Grid‑Connected Systems

Specification:

DP-100 High Voltage Differential Probe
Differential Voltage DC/AC peak 6.5kVp-p
Bandwidth (50Ω load -3dB) 100MHz
Common Mode Voltage DC/AC peak 6.5kVp-p
Common Mode Voltage RMS CATII / CATIII 6.5kVp-p
To Ground Maximum Voltage 3.25kVp-p CATIII
Attenuation(Switchable) x100, x200, x500, x1000
Input R (Each Input) 50MΩ, ±1%
Input C (Each Input) ≤2pF ±2%
Maximum Operation Voltage (DC + AC peak) ≤±650V at x500
≤±1.3kV at x1000
≤±3.25kV at x500
≤±6.5kV at x1000
Common Mode Rejection Ratio(CMRR) 60Hz: > 10000:1
100Hz: > 1000:1
1MHz: > 300:1
Noise (Into 50Ω Load) ≤1m Vrms
Input Impedance(Between Input) 54MΩ // 1.25pF
Accuracy (at 20-30°C 70%RH after 20minutes) ≤ ±1.5%
Maximum Output Voltage ±6.5Vp-p
Power Source External 9V DC Adaptor
Other Over Range Indication

Datasheet:

DP-100 Datasheet

CE marked
Powertek specializes in the design and manufacture of electrical power, voltage and current measuring instrumentation
Contact Powertek today