IRF Series clip-on split core current probe

The IRF series ruggedized current probes all utilize a flexible clip on current sense coil, allowing fast and safe installation, ideal for current monitoring in hostile arc-furness and smelting environments.
Models from 100Apk to 120,000Apk, optional 0-5V, 4-20mA, 1A or 5A output with Arms conversion. Wide Bandwidth up to 1MHz, to accommodate complex waveshapes, IP65 robust enclosure

Read more Get a quote

IRF-RMS AC Transducer rms input to dc output

  • 10kV rated compact sense coil fits in small spaces
  • Models from 100A to 120,000A
  • Works with all current waveshapes
  • Aperture sizes from 100mm to 2000mm
  • Basic traceable accuracy <0.2%
  • Instantaneous and rms converting models
  • Use with Modbus, SCADA systems and PLCs
  • Extend measurement range of data loggers and power analyzers

Products





IRF flexible split core current probe
IP65 enclosure to keep out water and contamination


Models  Arms/Apk
IRF3 - 450Arms / 600Apk
IRF15 - 2250Arms / 3000Apk
IRF30 - 4500Arms / 6000Apk
IRF60 - 9,000Arms / 12,000Apk
IRF150 - 22,500Arms / 30,000Apk
IRF300 - 45,000Arms / 60,000Apk
IRF600 - 90,000Arms / 120,000Apk

bullet

Peak Current ratings 100Apk to 120,000Apk

bullet

Sensitivity set to give ± 6 volts peak output(e.g. 1.0mV/A for ± 6000A peak ). 

bullet

Optional 1A or 5A output

bullet

RMS conversion option with a wide range of outputs: 0-100mV, 0-1V, 0-5V, 0-10V, 0-20mA,
4-20mA and 5-25mA

bullet

Wide Bandwidth 1Hz to 1MHz

bullet

Thin, flexible, clip-around coils (diameter 8.5mm) in lengths of 300, 500, 700, 1000 and 1500mm

bullet

Peak coil voltage isolation 10kV

bullet

Cable length (box to coil) of 2.5m.   Optional 4 metres lengths

bullet

+12Vdc,  +24Vdc, 110Vac, 230Vac power supply with 1kV isolation

bullet

IP65 robust enclosure

bullet

Low output impedance Min. output loading 10kohm (for rated accuracy)

bullet

CE marked

bullet

Accuracy <1% of reading

 





TA5V-5A or TA5V-1A output module - used for interfacing IRF & RCT probes to existing CT metering circuits
Casing: Din Rail
Bandwidth: TA5V-1A DC-10kHz TA5V-5A 25Hz-500Hz

Rating:  5VA
Accuracy: 1.0% accuracy

Input impedance: 100kohm
Accurate with waveform crest factors: 1 - 5
Input ranges: 10mV to 10V input
Power: 24Vdc, 110Vac or 230Vac power



Model TA5V-5A 1A or 5Arms output module


cthr01.jpg (30896 bytes)

External CTHrms converter module

 

IRF-RMS
External RMS converter
Bandwidth: DC-50kHz
Optional ac coupled version
0.5% accuracy
Input impedance 50ohm or 100kohm
Accurate with waveform crest factors: 1 - 5
Input ranges: 2mV to 50V input
Wide range of dc outputs:
0-100mV, 0-1V, 0-5V, 0-10V
0-20mA, 4-20mA and 5-25mA
Power: 12, 24, 48, 110Vdc, 110Vac or 230Vac power

Description

The robust IRF current probes all utilize a flexible clip on current sense coil, allowing fast and safe installation, ideal for current monitoring and retrospective fitting.  Using the optional 1A or 5A output, the IRF are a direct replacement for existing current transformer, completely compatible with installed CT circuits.

Many of the current transformer safety considerations can be eliminated using this technique, which produces safe low level signals even with no secondary burden or loading. With frequency bandwidths from 1Hz to 1MHz, the IRF is ideal for single and three phase power systems containing harmonics and distorted waveshapes.  Even PWM motor drive signals, chopped and pulsed waveforms can be measured accurately.  Using the optional IRF-rms converter, a dc output is produced making the IRF current probe ideal for control or system monitoring purposes. Typically the IRF clip on, clip around flexible coil current probe is used with SCADA systems, PLC, digital storage oscilloscopes, data loggers, power meters and power analyzers.
 

Powertek specializes in the design and manufacture of electrical power, voltage and current measuring instrumentation