DP-15k High Voltage Differential Probe

The differential probe DP-15k allows isolated and floating measurments with any oscilloscope or data recorder, allowing the oscilloscope to remain grounded.

Read more Get a quote

DP-15k, differential voltage probe for isolation and safety
DP-15k High Volatge Differential Probe

Highlights


  • Measure differential voltages up to 15kVp‑p
  • Max Input Voltage: ±7.5kV DC / 15kVp-p / 5.5kVrms AC
  • Bandwidth: DC-75MHz x100 range
  • Input Impedance 30MΩ / 1.5pF
  • Attenuator: x100, x1000
  • Max to ground voltage: 3.7kV CATIII
  • Output Impedance: 50Ω

  • Used to isolate DAQ, oscilloscope and data loggers
  • Perfect for power electronic systems and EV (electric vehicle) power systems
  • Allows isolated floating measurements
  • Prevents ground loops and common mode issues
  • Cablibration Certificate provided

Description

About the DP-15k Oscilloscope Differential Voltage Probe

The DP-15k differential voltage probes are an important accessory for any application involved in power electronics and high voltage systems. These probes allow isolated and floating measurments with any oscilloscope or data recorder, allowing the oscilloscope to remain grounded. Using a DP-15k Differential probe, differential and floating (isolated) measurements can be made on a variety of ac power systems like 460V/230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope or DAQ. The DP isolation probes are powered from a battery or power supply.

Applications

DP-100 Differential probe applications:

  • High‑impedance energy‑saving circuits
  • Motor drive inverter analysis
  • Monitoring IGBT/MOSFET gate drive signals
  • Thyristor and SCR controllers
  • Floating measurement where ground reference is unsafe
  • High‑voltage differential measurement up to 15kV
  • Switch Mode Power Supplies primary‑side waveform measuring
  • Thyristor and SCR controllers
  • Test labs needing safe HV measurement
  • Investigating ground loops and floating nodes
  • Motor drive PWM output analysis
  • Resonant converters
  • Motor inrush current observation

Specification:

DP-15k High Voltage Differential Probe
Differential Voltage DC/AC peak 1.5kVp-p x100
15kVp-p x1000
Bandwidth (50Ω load -3dB) 75MHz x100
20MHz x1000
Common Mode Voltage DC/AC peak 2.6kVrms
3.7kV DC
Common Mode Voltage RMS CATII / CATIII 2.6kVrms
To Ground Maximum Voltage 3.7kV CATIII
Attenuation(Switchable) x100, x1000
Input R (Each Input) 27.2MΩ, ±2%
Input C (Each Input) 3pF ±0.5%
Maximum Operation Voltage (DC + AC peak) ≤1.5V at x100
≤15kV at x1000
Common Mode Rejection Ratio(CMRR) 60Hz: > 10000:1
100Hz: > 1000:1
1MHz: > 300:1
Noise (Into 50Ω Load) ≤1m Vrms
Input Impedance(Between Input) 54MΩ // 1.5pF
Accuracy (at 20-30°C 70%RH after 20minutes) >2%
Maximum Output Voltage 8V
Power Source External 9V DC Adaptor
Other Over Range Indication

Full specifications for the differential probe DP-15k are available in DP-15k Datasheet

Powertek specializes in the design and manufacture of electrical power, voltage and current measuring instrumentation
Contact Powertek today