  • DP-25 Differential Voltage Probe:
  • Convinient upto 1000V
  • 25MHz frequency range
  • lower input impedence
  • Three attenuation ranges support
  • DP-65pro Differential Voltage Probe:
  • Higher Voltage tolerence
  • 65MHz frequency range
  • Reducing loading on sensitive circuits
  • Attenuation ranges: x20, x50, x200

About the DP-25 Oscilloscope Differential Probe

The DP‑25 is a 25 MHz high‑voltage differential probe designed for general‑purpose power electronics measurement. It allows safe oscilloscope observation of high‑potential signals that cannot be measured with standard single‑ended probes.

About the DP-65pro Oscilloscope Differential Probe

The DP‑65pro is a 65 MHz high‑performance differential probe built for modern high‑speed power electronics, including SiC and GaN systems. It offers significantly higher bandwidth, higher voltage tolerance, and much higher input impedance than the DP‑25.

DP-25 Differential probe:

  • High‑Voltage Differential Measurements
  • Power Electronics Switching Analysis
  • Current‑sense resistor measurements
  • Safety‑Critical Measurements
  • Noise‑Sensitive Differential Measurements
  • Power electronics research
  • Motor‑drive development
  • Solar inverter and charger testing

DP-65pro Differential probe:

  • Wide‑Bandgap Power Electronics device evaluation
  • High‑Speed Switching Analysis
  • Solar MPPT and inverter switching
  • High‑Bandwidth Noise & Transient Capture
  • High‑speed converter development
  • Industrial power module testing
  • Precision Differential Measurements
  • Used for SiC and GaN performance
DP-25 and DP-65pro Specifications
Function DP25 DP65pro
Differential Voltage DC + AC pk 1000V 1300V
Bandwidth (50ohm load -3dB) 25MHz (x50, x200) 65MHz (x50, x200)
Common Mode Voltage DC + AC pk 1000V 1600V
Common Mode Voltage RMS CAT|| / CAT||| 360Vrms 560Vrms
Attenuation x20, x50, x200 x20, x50, x200
Input R (Each Input) 2Mohm > 2% 9Mohm > 2%
Input R (Each Input) 2Mohm > 2% 9Mohm > 2%
Input C (Each Input) 2.3pF ±5% 2.3pF ±5%
Maximum Operation Voltage (DC + AC pk) ≤±100V at x20 ≤±160V at x20
≤±250V at x50 ≤±400V at x50
≤±1000V at x200 ≤±1600V at x200
Common Mode Rejection Ratio(CMRR) 60Hz > 10000:1 60Hz > 20000:1
100Hz > 1000:1 60Hz > 2000:1
1MHz > 300:1 1MHz > 600:1
Noise (Into 50ohm Load) ≤1.0m Vrms ≤0.7m Vrms
Input Impedance(Between Input) 4Mohm 1.32pF 18Mohm 1.2pF
Accuracy (at 20-30°C 70%RH after 20minutes) ≤ ±2% ≤ ±2%
Noise (Into 50ohm Load) ≤ ±5.0V ≤ ±5.0V
Input Impedance(Between Input) External 6V-9V DC External 6V-9V DC
Over Range Indication N/A Yes