The SD1000 phase meter offers superb accuracy, over a wide range of signal conditions. Conventional phase meters can become erratic when small levels of noise and distortion are present - the result is often unstable and incorrect phase readings. The SD1000 overcomes this by using Discrete Fourier Analysis (DFT) - to reject any noise and distortion without the need for tracking filters.
The SD1000 phase meter has totally isolated (floating) measurement inputs, allowing the user to connect anywhere in the circuit. This is very useful when the circuit under test does not have common grounds, eliminating accidental grounding and ground-loop currents. The user may choose voltage-voltage phase measurement, voltage to current phase measurement or current to current phase measurement, ideal for phase protection, power meters, energy meters and current transformer calibration
All measurements made with the SD1000 phase meter are traceable to National and International standards through the measurement standards of Powertek. The SD1000 is supplied with a certificate of conformance necessary for quality assurance standards such as ISO9001. A UKAS (independent measurement certification organisation) certificate is available.
SD1000 phase meter specifications
Phase | Range | ± 180.000° or 0.00° to +360.00° | |
Accuracy (23° ± 5°C; 1-year cal interval) | 0.5Hz to 100Hz | ± 0.02° ± 1 digit | |
>100Hz to 1kHz | ± 0.03° ± 0.005° /kHz ± 1 digit | ||
>1kHz to 100kHz | ± 0.04° ± 0.005° /kHz ± 1 digit | ||
>100kHz to 700kHz | ± 0.25° ± 0.005° /kHz ± 1 digit | ||
Resolution | 0.001° | ||
Repeatability | 0.005° ( ±0.003° via interfaces) | ||
Frequency | Range | 0.5Hz to 700 kHz | |
Accuracy | ±0.1% (23°C ± 5°C) | ||
Inputs | Voltage Range (operational) Current ranges using Options 02F/B All voltage and current input combinations are possible |
1mV rms to 350V rms (500Vpk) 20mA - 2Arms range Opt. 02F/B 1R00 5Hz - 20kHz 1.0Arms to 20Arms range Opt. 02F/B 0R01 5Hz - 20kHz |
|
Bandwidth | 0.5Hz to 700kHz | ||
Isolation (inputs to ground) | 2000V | ||
Impedance | 2 Mohm and 10pF | ||
Environment | Temperature | Operating | 0°C to + 50°C |
Storage | -40°C to +70°C | ||
Humidity (non-condensing) | 10% to 90% RH | ||
Dielectric Strength | Inputs to case or AC line input | 2kV AC 50/60Hz 1 minute | |
Power supply to case | 2kV AC 50/60Hz 1 minute | ||
Power Requirements | Line input voltage | 110V or 220V AC ± 10% | |
Line input frequency | 50/60Hz | ||
Line input fuse | 315mAT | ||
Line input conformance | IEC348 Class I; EN61000-3-2; EN61010 Class I; IEC801 Parts 1 to 4; EN55011 | ||
Power consumption | 25VA | ||
Mechanical | Weight | 5kg (6kg in delivery packaging) | |
Dimensions (W x H x D) | 215mm x 144mm x 390mm |