MC141 Portable calibrator

for voltage - current - temperature - resistance

MC141
  • Voltage range from 0 to 750V DC/AC with uncertainty 0.01%
  • Current range from 0 to 2A DC/AC with uncertainty 0.02%
  • Calibrated sinusoidal output signal DC - 1kHz
  • Set standard resistors from 10Ohm to 100MOhm in decade values with uncertainty 0.02%
  • TC temperature sensor simulation R, S, B, J, T, E, K, N in range from -250oC to 1850oC
  • Cold junction point automatic compensation with internal Pt100 sensor
  • RS232 interface c/w with USB convertor (IEEE488 as option)
  • Easy operation, large display Weight 5kg
  • UKAS/NIST Traceable
About the MC140 calibrator

The MC141 Multifunction calibrator is designed for portable and bench use in process control environments, calibration laboratories, quality departments and production lines where electrical instrumentation requires testing and calibration. Calibration of voltmeters to 750V ac/dc, ammeters to 2A ac/dc, resistance ranges of multimeters and industrial transducer units can be performed easily. RS-232 interface enables its use in automated calibration and testing systems. The Model MC141 can work under Powertek SW applications like WinQbase and Caliber.

DC/AC voltage
range % of value + % of range % of value + % of range % of value + % of range
DC 20Hz - 200Hz 200Hz - 1000Hz
0mV - 10mV * 0.05 + 0.0 + 10µV 0.20 + 0.05 + 20µV 0.20 + 0.10 + 20µV
10mV - 100mV 0.01 + 0.001 + 10µV 0.10 + 0.03 + 20µV 0.15 + 0.05 + 20µV
100mV - 1V 0.008 + 0.002 0.05 + 0.005 0.07 + 0.01
1V - 10V 0.008 + 0.002 0.05 + 0.005 0.07 + 0.03
10V - 100V 0.015 + 0.004 0.05 + 0.01 0.07 + 0.03
100V - 750V 0.018 + 0.004 0.03 + 0.02 0.10 + 0.03
*DC voltage from 0µV, AC voltage from 1mV
DC/AC current
range % of value + % of range % of value + % of range % of value + % of range
DC 20Hz - 200Hz 200Hz - 1000Hz
1µA - 200µA 0.05 + 0.0 + 20nA 0.25 + 0.0 + 20nA 0.30 + 0.10 + 20nA
200µA - 2mA 0.025 + 0.005 0.10 + 0.01 0.20 + 0.05
2mA - 20mA 0.015 + 0.003 0.07 + 0.005 0.20 + 0.05
20mA - 200mA 0.015 + 0.003 0.07 + 0.005 0.20 + 0.05
200mA - 2A 0.015 + 0.005 0.1 + 0.005 0.25 + 0.05
When option 140-50 Current coil is used, add 0.3% uncertainty to the set current value specified in the above table. Output current is multiplied by factor 25/50.
Frequency output
Frequency waveform square with fix amplitude 5Vpk-pk
Frequency range 0.1Hz to 2MHz
Frequency resolution 5 1/2 digit
TC temperature sensor simulation
Type R, S, B, J, T, E, K, N
Temperature range -250°C - 1820°C
Uncertainty 0.4°C až 3.2°C
Temperature scale ITS 90, IPTS 68
Manual and automatic compensation of cold junction temperature is available.
Resistance
Nominal value (Ohm) % of value
10 0.03 + 10mOhm
100 0.05
1 k 0.02
10 k 0.02
100 k 0.02
1 M 0.05
10 M 0.05
100 M 0.2

Accessories Included

Power line cable
1 pc
Operation manual
1 pc
Option 10/11: Test cable for 1000V - 20 A, black/red
2 pcs

Options

Option 140-50

Current coil with 25 and 50 turns.

Suitable for clamp ammeters and split core CTs, testing up to 1000 A. Maximum recommended output current into the coil is 20 Arms.

Option 100
Option 10

Test cable 20A/1000V (black)

Option 11

Test cable 20A/1000V (red)

Cable RS-232

RS-232, 2m

WinQbase

Application SW for making database of meters and for automatic meter calibration.

CALIBER

SW module for automatic calibration of multimeters.

Odering Information

MC141

Basic version with RS-232

MC141 GPIB